Neon sign flickering, dim or not lighting? How to find the cause

Most answers online for "neon sign flickering" are about LED neon flex. This one is for real glass neon: tubes, electrodes, GTO wire and a high-voltage transformer.

Safety first. A neon transformer puts out thousands of volts. Before you touch anything, unplug a plug-in sign, or shut a wired sign off at its disconnect switch and lock it off. A ground-fault protected transformer does not protect you from shock, and after a trip some models try to restart on their own, so treat a dark sign as live until it is unplugged. If you aren't trained for high-voltage work, leave the repair to a licensed sign electrician or an experienced neon tech.

Start with the symptom

The whole sign is dark

  • No power, or not enough. Check the outlet, breaker and switch first. Low line voltage is one of the most common problems: a 120V neon transformer needs at least 108V at its primary terminals.
  • The ground-fault protection tripped. Many neon transformers, including the channel letter transformers we carry, have secondary ground-fault protection. It shuts the transformer off when high voltage leaks to ground: moisture in or on the sign, tubing too close to metal, dirty insulators, or bugs and dirt. Fix the cause, then reset by turning the power off and back on.
  • Cord and outlet. Most neon transformers plug in with a cord: check the cord and plug for damage, and plug into a grounded three-prong outlet (without a ground, a fault can make the sign's metal live). On a hard-wired unit, the ground wire and hot and neutral have to be on the right terminals; one maker's unit won't light at all with them reversed.
  • A dead transformer. A burned-out transformer often can't make the tubes even flicker, and tar leaking profusely from the case seams means it's probably done. On a magnetic or core and coil unit, a tech can confirm with a short-circuit test on a milliammeter: a 30mA unit should read about 27 to 33mA, and a 15,000V unit is tested one side at a time. Don't load an electronic transformer with a milliammeter; it regulates its own output.

One tube or one section is dark

The tubes on one transformer output are wired in series, so one bad tube or one open connection stops the current for that whole circuit. On a magnetic transformer, a broken tube or open connection won't trip the ground-fault protection unless it also arcs to ground. That section just goes dark but can still be live, since an open circuit leaves the full starting voltage at the break, and an arc at a bad connection may not trip it either: a fire risk. Many electronic units, including Ventex, shut down on an open circuit.

  • AA Neon Tube Tester held to a neon tube, the tube glowing
    The AA Neon Tube Tester at work.
    Test each tube with an AA Neon Tube Tester. Touch its antenna to the glass or electrode wires: a tube with good gas lights with a pulsing glow, easy to see even in sun.
  • A bad tube can also go "flat": it may glow dimly, but it affects the circuit much like a dead tube.

Flickering, or blinking on and off

  • A leak to ground. After a ground-fault trip, some transformers try to restart (one maker's guide: three tries in about 10 seconds), so the sign can light, cut out and light again before it stays dark.
  • Drawing: long GTO runs from the transformer to the neon (no) and short GTO runs (yes)
    Keep the GTO from the transformer to the tubes as short as possible.
    Long GTO on an electronic transformer. Keep the high-voltage leads within the maker's limit (about 4 ft on Ventex) and out of metal conduit. Long or unequal GTO runs in conduit are a well-known cause of nuisance trips.
  • Arcing GTO. Damaged GTO looks melted or charred. High voltage goes looking for metal and can arc through the insulation, so watch for GTO zip-tied to a metal frame, laid across the transformer case or crossed over another GTO. Dampness makes it worse.
  • Too much tubing on the transformer. A transformer loaded to its limit has no reserve for cold nights, aging tubes or low line voltage, so the tubes can flicker or be slow to light. An overloaded Ventex electronic unit flashes and shuts itself off; turn it off and on to reset it.
  • A tube running low on gas. Flicker can mean an aging tube's gas pressure has dropped to a critically low point. A bender can often repump the tube.
  • A dimmer on an electronic transformer. Don't put a standard plug-in dimmer on a regular electronic transformer: our plug-in neon dimmers work with magnetic and core and coil transformers, not electronic ones. For a dimmed electronic sign, use one with dimming built in.

Dim tubes, or one dim end

  • Cold weather. Argon-mercury tubes (the blues, whites and most coated colors) can look dim and patchy in cold weather, especially right after they're switched on, until the mercury warms up. In hard cold they may stay dim. Neon tubes (the reds and oranges) are much less affected, though cold makes any tube harder to start.
  • Mercury migration. On an electronic transformer, the mercury in a long argon-mercury tube can drift toward one electrode. Dimming starts at one end and spreads. Swapping the two GTO leads at the transformer (with the power off) is a common field fix, but it only sends the mercury back the other way for a while. If it keeps coming back, call us.
  • A worn-out tube. A tube that is very dim except for a bright spot near the electrode, with black deposits at that end, has used up its gas. Switch it off: left running, the glass there can melt and let air in. It has to be remade.
  • Dark, mirror-like patches inside a coated tube point to contaminated mercury. The tube has to be remade.

Buzzing, crackling or arcing sounds

A neon sign should hum quietly. A loud buzz points to an old or overloaded transformer, GTO or tubes too close to metal, glass bends too close together, or loose conduit fittings. A snap or crackle is arcing: shut the sign off and look for burn marks on the GTO, boots and housings.

Checks worth making

  • Measure the footage. Add up the tubes plus 1 ft per tube for its pair of electrodes, and compare that with the transformer's chart. Our rule is no more than 90% of the chart, and at least 70% for core and coil (the CC3508 and CC5010 are the exceptions). Our Footage Calculator does the math, and How to size a neon transformer explains it.
  • Check clearances. Keep the high-voltage connections clear of grounded metal as the NEC and the transformer maker require: 1 1/2 in. is the common figure, and high-frequency electronic circuits can need more. Where they can't be, the connection belongs in a listed electrode enclosure, a glass or porcelain housing.
  • Read the load. Our neon testing gear includes the Neon Load Tester, which connects to the electrodes in place of the transformer and shows the voltage the tubes need, so you can check that the transformer is the right size.

What usually fixes it

If you aren't trained for high-voltage work, leave these fixes to a licensed sign electrician or an experienced neon tech.

  • Wet-location neon housing front caps
    Wet-location front caps keep water out of the housing.
    Burnt or damaged GTO: replace the run with new GTO wire, kept short and away from metal and other GTO. Avoid splices. If you must splice, heat shrink, tape and wire nuts aren't good enough: our neon splice kits page has the last few ready-made splice boxes and the parts some techs use for a home-made splice.
  • Wet, dirty or worn connections: new end caps (boots), plus front caps, gaskets and spring rebuild kits from our housing accessories. Most neon failures trace back to the high-voltage wiring, and water is one of the most common causes. Outdoors, boots and receptacles must be wet-location listed.
  • Tubes too close to metal: remount them on listed tube supports, never metal ones.
  • Cartoon of a neon electrode saying: Oh no, my electrode wires broke off! Now what do I do?
    Broken electrode wires: if the sign uses glass housings, a brass Fixer Cap can bring a 15mm tube back without repumping. Fixer Caps are made to be used inside a glass housing only; as a bare repair they aren't safe. Otherwise a bender remakes the tube with new electrodes.
  • A dead or wrong-size transformer: replace like with like. An electronic transformer is not a direct replacement for an old magnetic one, even when the footage matches. We carry electronic, channel letter, core and coil, dimming and flashing, and 12-volt transformers. For an old magnetic transformer, including the common 15,000V unit, call us: we don't stock a magnetic replacement today.
  • An old animated sign that stopped: often the transformer, the flasher or both. The originals were custom-built, so call us about restoring the whole package. If only the flasher died, one of our plug-in flashers can take its place; on a magnetic transformer, pick one with delayed turn-on circuitry (the #2 through #7), which protects the flasher from the transformer's voltage spikes.

Call 480-820-9517 and describe the symptom: what's dark or flickering, when it started, the weather, and the transformer's label.